Model PS-DC Remote Amplifier Control Unit Specifications

PARAMETER

SPECIFICATIONS

OUTPUT

 

Voltage

±15V

Maximum Voltage Error (No Load)

± 200mV

Ripple Voltage (No Load)

± 200mV

Maximum Source Resistance

1 ohm

Power Supply Rejection

50dB

Temperature Coefficient

0.02% / °C

Maximum Current

1 A

Maximum Transient Response

500 µs

Input

 

Voltage

10 to 36 VDC

Max Current @ Full Load

5 A

Environment

 

Operation

-25°C to +70°C (-13°F to +158°F)

Storage

-50°C to +100°C (-58°F to +212°F)
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: November 2, 2009 10:35 AM