AMP-TC Series Modular Spinning Thermocouple Amplifier Specifications

PARAMETER

SPECIFICATION

OUTPUT

Output is not linearized over temperature, if necessary, the output may be linearized externally

Range

±10V Max

Sensitivity @ 25°C TC Temperature

10mV/°C

Capacitive Load

1000 pF Max

Temperature error

Includes errors due to nonlinearity over temperature in cold junction compensation

Initial @ 25°C Case Temperature

± 1°C Max

-25°C to +85°C Case Temperature

± 2°C Max

-55°C to +125°C Case Temperature

± 5°C Max

Noise

Referred to input of amplifier

0.01 - 10Hz

0.8 µV p-p

Dynamic Response

 

Frequency Response (-3 dB)

1.56 kHz (Higher Bandwidths Available)

Slew Rate

0.4 V/ µs

Settling time 0.1% / 0.01%

40 µs/ 50 µs

Power Requirements

 

Voltage

±15 VDC

Current

±10 mA Max Total (2 channels)
±15 mA Max Total (3 channels)

Environment

  

Specification

-25°C to +85°C (-13°F to +185°F)

Operation

-55°C to +125°C (-67°F to +257°F)
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: May 14, 2008 11:04 AM