logo Michigan Scientific Corporation

About Us | Contact Us | Site Map | Links | Help | Chinese | Tech Notes | White Papers
Bookmark and Share

AMP-TC*-LIN Linearizing Thermocouple Amplifier Specifications

PARAMETER

SPECIFICATION

INPUT

           Range
-80°C to 1000°C

OUTUT

Range

± 10 V

Sensitivity @ 25°C TC Temperature

10 mV/°C

Capacitive load

1000 nF

TEMPERATURE ERROR

Includes errors due to cold junction compensator

-40°C to +70°C Case Temperature

± 3°C Max

-40°C to +110°C Case Temperature

± 5°C Max

DYNAMIC RESPONSE

 

Frequency Response -3dB

10Hz

Slew rate

.00025V / µs

Settling Time 1%

80ms

POWER REQUIREMENTS

Voltage

± 15 VDC

Quiescent Current

± 10 mA

ENVIRONMENT

Specification

-40°C to +70°C ( -40 to +158°F)

Operation

-40°C to +125°C ( -40 to +257°F)

MECHANICAL (without connectors)

            Weight
9.2 g (0.324oz.)
             Overall Lenght
30.99 mm(1.220 in)
             Overall Height
5.46 mm (0.215 in)
             Overall Width
19.23 mm (0.757 in)