TR3D-A-1K |
TR3D-A-3K |
TR3D-A-5K |
TR3D-A-5K |
|
Maximum Load Capacity (per channel) |
1000 lbs (454 kgf) | 3000 lbs (1361 kgf) | 5000 lbs(2268 kgf) | X & Y axes 5000 lbs(2268 kgf) Z axis 10000 lbs (4536 kgf) |
Full Scale Load (per channel) |
1000 lbs (454 kgf) | 3000 lbs (1361 kgf) | 5000 lbs (2268 kgf) | X & Y axes 5000 lbs(2268 kgf) Z axis 10000 lbs (4536 kgf) |
| Full Scale Output | 4.0 mV/V, nominal, all channels | |||
| Sensor | 3 Four-arm strain gage bridges | |||
| Nonlinearity | <0.5% of full scale output |
|||
| Hysteresis | <0.05% of full scale output | |||
| Repeatability | <0.05% of full scale output | |||
| Zero Balance | Within ± 10.0% of full scale output | |||
| Temperature Range, Compensated** | 75°F to 200°F (24°C to 93°C) | |||
| Temperature Effect on Zero | <0.5% full scale | |||
| Temperature Range, Useable | -40°F to 300°F (-40°C to 149°C) | |||
| Excitation Voltage, Maximum | 10V DC or AC rms | |||
| Insulation Resistance, Bridge/Case | Exceeds 5000 MΩ | |||
| Standard Cable Length | 10 ft (3.05 m)shielded, open-ended leads | |||
| **Contact factory for other compensated ranges. | ||||