LW12.8 Wheel Load Transducer Specifications
| Maximum Force Capacity, [Fx, Fz] Radial |
12,000 lb (53.4 kN) |
| [Fy] Lateral at Tire Patch |
6,000 lb (26.7 kN) |
| Maximum Torque Capacity |
6,000 lb-ft (8.1 kN-m) |
| Full Scale Output |
0.8 mV/V nominal |
| Sensor |
4 arm strain gage bridges |
| Nonlinearity |
<1% of full scale output |
| Hysteresis |
<1% of full scale output |
| Repeatability |
Within 1% of full scale output |
| Zero Balance |
Within ± 5.0% of rated output |
| Cross Axis Sensitivity |
<2% of full scale output with amplifier |
| Radial Sensitivity Variation |
<1% of full scale output |
| Bridge Resistance |
175 to 1400 ohm, axis dependent |
| Temperature Range, Compensated |
-40°F to 200°F (24°C to 93°C) |
| Operating |
-40°F to 257°F (-40°C to 125°C) |
| Insulation Resistance, Bridge/Case |
Exceeds 1000 Megohm |
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated:
May 14, 2008 11:04 AM