logo Michigan Scientific Corporation

About Us | Contact Us | Site Map | Links | Help

LW-1T-25K Wheel Load Transducer Specifications

Maximum Force Capacity, [Fx, Fz] Radial 25,000 lb (111.2 kN)
[Fy] Lateral at Tire Patch 12,500 lb (55.6 kN)
Maximum Torque Capacity, [Mx, My, Mz] 20,000 lb ft (27.1 kN-m)
Full Scale Output 1 mV/V nominal
Sensor 4 arm strain gage bridges
Nonlinearity Less than 1% of full scale output
Hysteresis Less than 1% of full scale output
Repeatability Within 1% of full scale output
Zero Balance prior to installation Within 2% of rated output
Cross Axis Sensitivity <2% of full scale with amplifier
Temperature Range, Compensated -40°F to 200°F (-40°C to 93°C)
Operating -40°F to 257°F (-40°C to 125°C)
Radial Sensitivity Variation <1%
Bridge Resistance 700 to 140 ohm, axis dependent
Insulation Resistance, Bridge/Case Exceeds 1000 Megohm
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: May 14, 2008 11:04 AM