logo Michigan Scientific Corporation

About Us | Contact Us | Site Map | Links | Help

Series 320 Multi-Channel Digital Telemetry System Specifications

PARAMETER

SPECIFICATION

TRANSMITTER:

Data transmission method

2.4GHz FSK

Analog channels

6 (configurable for full bridge or thermocouple)

Bridge drive excitation voltage

3.0VDC

Bridge amplifier input range

customer specified

Channel filter selection

2-pole low-pass, customer specified (1kHz typ)

Data sampling rate

3kHz all channels sampled simultaneously

System resolution

12 bits  

Channel-to-channel skew

negligible (sample and hold)

Operating temperature

-40°F to +257°F  (-40°C to +125°C)

Power requirement

4 to 16VDC  /  20mA

Dimensions (L x W x H)

1.50 x 1.60 x 0.35 in.  (38.1 x 40.64 x 8.89 mm)

Weight

0.88oz. (25g)
 
 

RECEIVER:

Output at full scale

±10V

Output resolution

0.0244%

Channel filter type

2-pole low-pass
Channel filter selection
100Hz, 1kHz
Current output per channel
±10mA
Operating temperature
-40°F to +158°F  (-40°C to +70°C)
RF antenna connector
reverse polarity SMA

Power requirement

9 to 36VDC  /  500mA
Dimensions (L x W x H)
9.25 x 3.5 x 1.75 in.  (235 x 88.9 x 45.47 mm)
   

SYSTEM GENERAL:

 
Total system delay (unfiltered data)
< 670us Max
RF channels available
16 Min
   
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: May 14, 2008 11:04 AM