logo Michigan Scientific Corporation

About Us | Contact Us | Site Map | Links | Help | Chinese | Tech Notes | White Papers
Bookmark and Share

Model FO-RCT/RR Fiber-Optic Systems Relay Control Link Specifications

PARAMETER

SPECIFICATION

SYSTEM CHARACTERISTICS AND PERFORMANCE

GENERAL

Single Contact

Four Contacts

Power
Power Source
3-AA Alkaline Batteries
Battery Life
up to 8 days continuous
Stimulus on Transmitter

High Level Input Voltage

Min: 2.4 VDC, Max: 20 VDC
Low Level Input Voltage
Min: -20 VDC, Max: 0.6 VDC
Switch Input Type
TTL/CMOS or Toggle Switch
Stimulus Response Time
< 200 ms typical
Relays 1
Max Switching Voltage per Contact
30 VDC or 120 VAC
Max Switching Power per Contact
3600 VA
150 W (600 VA)
Max Switching Current per Contact
30 Amps
5 Amps
Max Relay Operating Rate (@ Rated Load) 2
10 cpm
2 cps
Minimum Permissible Load (@ 5 VDC)
100 mA
10 mA

PHYSICAL

Channels
1 SPST Relay
4 SPST Relays
Dimensions (L x W x H)
6.5x2.3x1.35in (165x58x34 mm)
Volume
<20.2 in³ ( <325.4 cm³)
Weight
13 oz (404 g)
Input Connectors
BNC x 4
Output Connector
2-pin D-SUB (9-pin Shell)
9-pin D-SUB
Optical Connectors
ST
Optical Cables
multi-mode graded-index 62.5/125 or 100/140 μm
Optical Cable Length
1640 ft (500 m) max.

ENVIRONMENTAL

Operating Temperature
-4 F to +150 F (-20 C to +65 C)
Operating Humidity
85% R.H. max. non-condensing
EMC
300 V/m at 500 kHz to 1 GHz, 200 V/m at 1 GHz to 11 GHz, and 600 V/m (pulsed 5% duty-cycle & 5μs rise-time) 1 GHz to 2 GHz
1 Other configurations available upon special request (ie. DPDT, 60A SPST, signal relays)
2 System internally limited to approximately 2 cps

             FO-RCT/RR CONNECTOR                FO-RCT/RR CONNECTOR PIN OUT TABLE

 

Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: November 2, 2009 10:35 AM