PARAMETER |
SPECIFICATION |
|
SYSTEM CHARACTERISTICS AND PERFORMANCE |
||
GENERAL |
Single Contact |
Four Contacts |
Power |
||
Power Source |
3-AA Alkaline Batteries |
|
Battery Life |
up to 8 days continuous |
|
Stimulus on Transmitter |
||
|
Min: 2.4 VDC, Max: 20 VDC |
|
Low Level Input Voltage |
Min: -20 VDC, Max: 0.6 VDC |
|
Switch Input Type |
TTL/CMOS or Toggle Switch |
|
Stimulus Response Time |
< 200 ms typical |
|
Relays 1 |
||
Max Switching Voltage per Contact |
30 VDC or 120 VAC |
|
Max Switching Power per Contact |
3600 VA |
150 W (600 VA) |
Max Switching Current per Contact |
30 Amps |
5 Amps |
Max Relay Operating Rate (@ Rated Load) 2 |
10 cpm |
2 cps |
Minimum Permissible Load (@ 5 VDC) |
100 mA |
10 mA |
PHYSICAL |
||
Channels |
1 SPST Relay |
4 SPST Relays |
Dimensions (L x W x H) |
6.5x2.3x1.35in (165x58x34 mm) |
|
Volume |
<20.2 in³ ( <325.4 cm³) |
|
Weight |
13 oz (404 g) |
|
Input Connectors |
BNC x 4 |
|
Output Connector |
2-pin D-SUB (9-pin Shell) |
9-pin D-SUB |
Optical Connectors |
ST |
|
Optical Cables |
multi-mode graded-index 62.5/125 or 100/140 μm |
|
Optical Cable Length |
1640 ft (500 m) max. |
|
ENVIRONMENTAL |
||
Operating Temperature |
-4 F to +150 F (-20 C to +65 C) |
|
Operating Humidity |
85% R.H. max. non-condensing |
|
EMC |
300 V/m at 500 kHz to 1 GHz, 200 V/m at 1 GHz to 11 GHz, and 600 V/m (pulsed 5% duty-cycle & 5μs rise-time) 1 GHz to 2 GHz |
|
1 Other configurations available upon special request (ie. DPDT, 60A SPST, signal relays) |
||
2 System internally limited to approximately 2 cps |
||