logo Michigan Scientific Corporation

About Us | Contact Us | Site Map | Links | Help

Model LWEH-6L 6 Channel Rotating Amplifier Module Specifications

PARAMETER

SPECIFICATION

BRIDGE EXCITATION

 

Type

DC Constant Voltage (Bipolar excitation)

Magnitude

10 Volts

Accuracy

0.40%

Temperature Coefficient

0.0005%/°C Max (0.00028 %/°F)

Current Limit

84 mA/channel

REMOTE CALIBRATION

Positive & negative shunt calibration

Shunt Resistance

Matched to Wheel Load Transducer Range

Shunt Accuracy

0.50%

GAIN

Matched to Wheel Load Transducer Range

Range w/ jumper

100 & 2000 V/V

w/ external resistor

100 through 2000 V/V

Accuracy @ 25°C, Gain =100

              @ 25°C, Gain =1000

±0.05 %typ (±0.50 % max)
±0.50 %typ (±1.0 %max)

Temperature Coefficient

0.0025 %/°C (0.0014 %/°F)

OUTPUT

 

Range

±10V Max

Capacitive Load

1000 pF Max

VOLTAGE OFFSET

Referred to input of amplifier

Initial @ 25°C

±10 µV

Temperature Stability

±0.1 µV /°C

Time Stability

±1.0 µV / Month

DC CMRR

160 dB

Noise         rti 0.01 to 10 Hz

0.7 µV p-p

DYNAMIC RESPONSE

 

Frequency Response @Gain=1000

                           -3dB @ Gain=100

1 kHz
10 kHz

Slew rate

0.5 V/ µs

Settling Time to 0.01%@ Gain=100

145 µs

POWER REQUIREMENTS

 

Voltage @ 25°C

±13 to ±17 VDC

Current

±100 mA plus Bridge Load (+100 mA additional during shunt calibration)

ENVIRONMENT

 

Specification

-25 to +85°C (-13 to +185°F)

Operation

-55 to +125°C (-67 to +257°F)

MECHANICAL

 

Weight

1.2 kg (2.5 lbs)
Version: 3.0 | ©2005 Michigan Scientific Corporation | Updated: May 14, 2008 11:04 AM