PARAMETER |
SPECIFICATION |
BRIDGE EXCITATION |
|
|
DC Constant Voltage (Bipolar excitation) |
|
AMP-SG-M1-5 ±2.5 V (5 volts total) AMP-SG-M1-10 ±5.0 V (10 volts total) |
|
0.40% |
|
0.0005 %/°C Max (0.00028 %/°F) |
|
AMP-SG-M1-5 42 mA AMP-SG-M1-10 84 mA |
REMOTE CALIBRATION |
Positive & negative shunt Calibration |
|
|
internal values |
100kΩ and 1MΩ |
| external values |
100kΩ Through 1MΩ |
|
|
| @ 100 kohm |
0.01% |
| @ 1Megohm |
0.01% |
GAIN |
|
|
|
| with external jumper |
100 or 2000 V/V |
| w/ external resistor |
100 to 2000 V/V |
|
|
| @ 25°C, Gain =100 |
±0.05 % typ (±0.50 %max) |
| @ 25°C, Gain =1000 |
±0.50 %typ (±1.0 %max) |
|
0.0025 %/°C (0.0014 %/°F) |
OUTPUT |
|
|
±10V Max |
|
1000 pF Max |
VOLTAGE OFFSET |
Referred to input of amplifier |
|
±10 μV typ (±50 μV max) |
|
±0.1 μV / °C typ (±0.25 μV / °C max) |
|
±0.1 µV / month |
|
160 dB |
NOISE |
|
|
0.7µV p-p |
DYNAMIC RESPONSE |
|
|
|
@ Gain=1000 |
20 kHz |
| @ Gain=100 |
20 kHz |
|
4 V/ µs |
|
9 µs |
POWER REQUIREMENTS |
|
|
±15 VDC |
|
±15 mA plus Bridge Load (+15 mA additional during shunt calibration) |
ENVIRONMENT |
|
|
-40 to +85°C (-40 to +185°F) |
|
-40 to +125°C (-40 to +257°F) |
MECHANICAL |
AMP-SG-M1 |
|
14.17 G (0.50 Oz) |
|
31.75 mm (1.250 in) |
|
6.35 mm (0.250 in) |
|
20.32 mm (0.800 in) |